How to Configure XP-SNET Controller for Global Antipassback (GAC) Application

How to Configure XP-SNET Controller for Global Antipassback (GAC) Application

Problem (Issue) Statement

How to configure XP-SNET Controller for Global Antipassback (GAC) Application

Description:

A guide to configure XP-SNET controller for Global Antipassback (GAC) application


Note

XP-SNET-GAC controller is only supported for LAN Network Communications only.

.

Tip

Controller models supported as GAC Client: XP-SNETv3.36, XP-SNETv4, XP-M2000i v6.10 and above, and XP-M1000i v6.00 and above.

Related Software:

  • xPortalNet v1.5.0.90 above

Related Hardware:

  • XP-SNET_GAC v2.24
  • XP- SNETv2 v3.36 and above

System Application:

  • Global Antipassback feature

Symptom and Finding:

NIL

Cause:

A guide to configure XP-SNET controller for Global Antipassback (GAC) application.

Solution:

Warning!

XP-SNET-GAC currently do not support odd numbered card lengths, e.g. 5, 7, 9 card number lengths.

Summary:


Step-by-step Guide:

  • To perform ColdStart for first power up:

Step 1: Press & hold COLDSTART button on XP-SNET board.


Step 2: Press & release RESET button on XP-SNET board.


Step 3: Wait for STAT & CPU LED to light up simultaneously.


Step 4: Release COLDSTART button.


Note

User are advised to perform ColdStart operation once after every first time power up of the controller; or when advised to do so by the technical support.



  • To perform pre-configuration setting for the network connection:

Knowledge Base Link

User may refer How to Pre-configure Network Connection for IP Controllers to complete the process.



  • To configure IP Address for XP-SNET:

Knowledge Base Link

User may refer How to Configure IP Address for IP Controllers to complete the process.



  • To configure XP-SNET-GAC IP Address as the Master IP Address:

Knowledge Base Link

This configuration process must be configured on XP-SNET controllers with firmware v3.71 or lower.


Step 1: After completing the process to configure the IP address. Users should scroll down the Network Setting page.


Step 2: Configure the Master Controller IP Address and Master Controller Port as XP-SNET-GAC's IP address and communication port respectively. Click Submit to save the changes made.
Configuring Master Controller IP Address and Master Controller Port
Figure 1: Configuring Master Controller IP Address and Master Controller Port

Common Issue

NIL

Date Documentation:

3/10/2018 (Rev 1.0)

PROOF-READ

.

.


.

Related content

How to Configure and Setup XP-SNET-GAC
How to Configure and Setup XP-SNET-GAC
More like this
How to Configure Global AntiPassback Controller (GAC) Settings in xPortalNet Server
How to Configure Global AntiPassback Controller (GAC) Settings in xPortalNet Server
More like this
How to Enable AntiPassback Feature for Multi-Door Controllers
How to Enable AntiPassback Feature for Multi-Door Controllers
Read with this
How to Enable Client GAC Controller Setup in xPortalNet Client
How to Enable Client GAC Controller Setup in xPortalNet Client
More like this
How to Configure Door Zone Code for AntiPassback Application
How to Configure Door Zone Code for AntiPassback Application
Read with this
How to Configure AntiPassback settings for Single Door Controller in xPortalNet Software
How to Configure AntiPassback settings for Single Door Controller in xPortalNet Software
More like this

© MicroEngine Technology Sdn Bhd (535550-U). All rights reserved.