How to Connect XP-SR40 Controller to Door Accessories

Problem (Issue) Statement:

How to connect XP-SR40 controller to door accessories

Description:

XP-SK40 is MicroEngine's legacy standalone controller. This article will guide users on how to connect the controller to the door accessories.

Related Software:NIL
Related Hardware:
  • XP-SR40
System Application:NIL
Symptom and Finding:NIL
Cause:For first time guide on how to connect XP-SR40 to the door accessories.
Solution:

Summary:

  • Wiring diagram to connect XP-SR40 controller to door accessories.

.

Step-by-step Guide:

  • Wiring diagram to connect XP-SR40 controller to door accessories:

Step 1: Please refer to the following wiring diagram for the connections between the XP-SR40 controller to the door accessories:
Wiring Diagram for XP-SR40 Controller to Door Accessories
Figure 1: Wiring Diagram for XP-SR40 Controller to Door Accessories

.

Step 2: Power ON the controller by connecting it to a power supply with 12VDC and 3A current rating. Ensure that when the door security status is ON, the EM lock is in locked condition and vice versa.

.

Step 3: Ensure that when users pressed the exit button, the EM lock is released and the LED on MAS-RB2 is turned on when the EM lock is released.

Common Issues:NIL
Porting Date:27/3/2019

PROOF-READ

.

.


.

© MicroEngine Technology Sdn Bhd (535550-U). All rights reserved.