How to Connect XP-GLS5000 Controller to XP-SNET-E32R Extension Board for Lift Masking System Application

Problem (Issue) Statement:

How to connect XP-GLS5000 controller to XP-SNET-E32R extension board for Lift Masking System application

Description:

A guide to connect XP-GLS5000 controller to XP-SNET-E32R extension board for Lift Masking System application

Related Software:

  • xPortalNet HS v1.8.0.7 and above

Related Hardware:

  • XP-GLS5000 v1.16
  • XP-SNET-E32R

System Application:

  • Lift Masking System application

Symptom and Finding:

NA

Cause:

For first time connection between XP-GLS 5000 controller with XP-SNET-E32R extension board for Lift Masking System application.

Solution:

Summary


Step by step Guide:

  • To configure XP-GLS 5000 to operate in Lift Controller Mode

Step 1: Ensure that the XP-GLS5000 controller is configured to Lift Controller Mode.

Knowledge Base Link

Users may refer to How to Assign XP-GLS5000 Controller to Function as Lift Controller for the complete steps.



  • To connect XP-SNET-E32R extension board to XP-GLS 5000 controller:

Step 1: Please follow the wiring diagram as shown below.

Figure 1: Wiring Diagram between 4 XP-SNET-E32R Extension Boards to XP-GLS5000 Controller


Step 2: The table below indicates the XP-SNET-E32R address settings and the corresponding relay number ranges available for floor zone settings in the software.



  • To configure DIP switches for address setting on XP-SNET-E32R extension board:

Knowledge Base Link

Users can refer to How to Configure Address Unit No on XP-SNET-E32R Extension Board  for the complete procedures on configuring the address settings on XP-SNET-E32R extension board.