How to Perform the ColdStart Operation for MicroEngine Standalone Controllers

Problem (Issue) Statement:

How to perform the ColdStart operation for MicroEngine standalone controllers

Description:

This article will guide users on how to perform the ColdStart operation for MicroEngine standalone controllers.

ColdStart operation must be performed if users forgot the MasterPIN to enter the Programming Menu to reset the MasterPIN to default settings.

Related Software:NIL
Related Hardware:
  • XP-SR200K
System Application:NIL
Symptom and Finding:

NIL

Cause:For first time guide on how to perform the ColdStart operation for MicroEngine standalone controllers.
Solution:

The ColdStart Operation will erase all the memory in the controller and reset all the settings to default. Proceed only if you are sure you want to reset the controller to default settings!

.

.

Summary:

  • To perform ColdStart operation for MicroEngine standalone controllers.

.

Step-by-step Guide:
  • To perform ColdStart operation for MicroEngine standalone controllers:

Step 1: Switch off the power for the controller.

.

Step 2: Upon switching on the reader, it will enter the power up mode. The Red LED will be blinking at this stage for 10 seconds.

.

Step 3: In the power up mode while the Red LED is blinking, press and hold the exit button for 2 seconds. The controller will then reset to factory default settings. All the card users will also be cleared from the controller memory.

.

Note

The default MasterPIN for MicroEngine standalone controllers is "123456". Users are advised to change the MasterPIN after performing the ColdStart operation.

Common Issues:

NIL

Porting Date:16/01/2020

PROOF-READ

.

Related Articles.

Containing the label "xp-sr200k"

Filter by label

There are no items with the selected labels at this time.

.


.

© MicroEngine Technology Sdn Bhd (535550-U). All rights reserved.