How to Reset the XP-M1000x Controller to Factory Default Setting (ColdStart)

Problem (Issue) Statement:How to reset the XP-M1000x Controller to factory default setting (ColdStart)
Description:If users forgot the Master PIN which is used to enter the programming menu for XP-M1000x controller, users must ColdStart the controller to revert back to Default Master PIN.
Related Software:NIL
Related Hardware:
  • XP-M1000x
System Application:NIL
Symptom and Finding:NIL
Cause:For first time guide to reset the XP-M1000x controller to factory default settings (ColdStart).
Solution:

Warning!

The ColdStart operation will erase all the memory in the XP-M1000x and reset all the settings to default. Proceed only if you are sure you want to reset the controller to default settings!


Summary:

  • To perform ColdStart for the controller.


Step-by-step Guide:

  • To perform ColdStart for the controller:

Step 1: Turn off the power supply to the controller.


Step 2: Turn on the power supply to the controller again. The screen below will be shown and the red LED will be blinking for 10 seconds.
Controller Starting Screen
Figure 1: Controller Starting Screen


Step 3: During this 10 seconds period where the red LED is blinking, press and hold the ColdStart button at the back of the reader for approximately 2 seconds until the screen displays the following message. The controller will sound a very long beep. Wait until the ColdStart process completes.
Cold Start Screen
Figure 2: Cold Start Screen


Step 4: When the ColdStart process completes, the following Idle Mode screen will be shown. The following table explains the normal response in Idle Mode.
Idle Mode Screen
Figure 3: Idle Mode Screen




Note

Please check and ensure that the Mode jumper at the back of the controller is left open, which will allow the XP-M1000x to operate in controller mode instead of reader mode. After setting the XP-M1000x in controller mode, users can then proceed to enter Programming Menu.

Mode Jumper Setting Behind XP-M1000x
Figure 4: Mode Jumper Setting Behind XP-M1000x

Common Issues:NIL
Porting Date:30/11/2018 (Rev 1.0)

PROOF-READ

.

.


.