How to Reset the XP-M1000x Controller to Factory Default Setting (ColdStart)

How to Reset the XP-M1000x Controller to Factory Default Setting (ColdStart)

Problem (Issue) Statement:

How to reset the XP-M1000x Controller to factory default setting (ColdStart)

Description:

If users forgot the Master PIN which is used to enter the programming menu for XP-M1000x controller, users must ColdStart the controller to revert back to Default Master PIN.

Related Software:

NIL

Related Hardware:

  • XP-M1000x

System Application:

NIL

Symptom and Finding:

NIL

Cause:

For first time guide to reset the XP-M1000x controller to factory default settings (ColdStart).

Solution:

Warning!

The ColdStart operation will erase all the memory in the XP-M1000x and reset all the settings to default. Proceed only if you are sure you want to reset the controller to default settings!

 

Summary:

  • To perform ColdStart for the controller.

 

Step-by-step Guide:

  • To perform ColdStart for the controller:

Step 1: Turn off the power supply to the controller.

 

Step 2: Turn on the power supply to the controller again. The screen below will be shown and the red LED will be blinking for 10 seconds.


Figure 1: Controller Starting Screen

 

Step 3: During this 10 seconds period where the red LED is blinking, press and hold the ColdStart button at the back of the reader for approximately 2 seconds until the screen displays the following message. The controller will sound a very long beep. Wait until the ColdStart process completes.


Figure 2: Cold Start Screen

 

Step 4: When the ColdStart process completes, the following Idle Mode screen will be shown. The following table explains the normal response in Idle Mode.


Figure 3: Idle Mode Screen

 

 

 

Note

Please check and ensure that the Mode jumper at the back of the controller is left open, which will allow the XP-M1000x to operate in controller mode instead of reader mode. After setting the XP-M1000x in controller mode, users can then proceed to enter Programming Menu.


Figure 4: Mode Jumper Setting Behind XP-M1000x

Common Issues:

NIL

Porting Date:

30/11/2018 (Rev 1.0)

PROOF-READ

.

.


.

© MicroEngine Technology Sdn Bhd (535550-U). All rights reserved.