Step 1: Open xPortalNet Comm Service.
Step 2: Ensure that the xPortalNet Comm Service Status is Running.
Figure 1: xPortalNet Comm Service Running Pop-up message
Step 3: Right-click the xPortalNet Comm Service icon at the notification bar, click Check Service Info and verify that the software detects the plugged in USB license key.
Figure 2: Valid software license key detected indication
.
.
Step 1: For Connection Setup, open xPortalNet Server > Server Admin > Connection Setup. The Connection Setup window will be shown as below:
Figure 3: Connection Setup window
Step 2: Click Add to add a new connection. The Add Connection window will be shown as below. Click OK to save the changes.
Figure 4: Add Connection window
Step 3: For Controller Setup, go to Server Admin > System Device Setup > Controller. The Controller Setup window shown as below:
Figure 5: Controller Setup window
Step 4: Click Add to add a new controller. The Add Controller window will be shown as below. Click OK to save the changes.
Figure 6: Add Controller window
Step 5: For Door Setup, go to Server Admin > System Device Setup > Door. The Door Setup window shown as below:
Figure 7: Add Door window
Step 6: The screenshots below indicate several examples of how to configure the door settings following different scenarios.
Figure 8: Add Door setting example with Plato readers connected directly to controllers (via Downlink port)
.
.
.
Figure 9: Add Door setting example with Plato readers connected to MK800E Reader Interface Module, which is then connected to the controllers
.
.
.
Figure 10: Add Door setting example with third party reader connected directly to the TTL port on the controllers
.
.
.
Info |
---|
|
- TTL In / Out Reader No configuration settings are only applicable when the third party reader is connected directly to the TTL port.
- XP-SNET controller supports up to a maximum of 5 TTL reader connections.
|
.
.
Figure 11: Add Door setting example with third party reader connected to MK800E Reader Interface Module, which is then connected to the controllers
.
.
.
Info |
---|
|
- Users have to set a unique Door Unit Number for different doors for identification purposes (i.e.: no two doors in the same controller can have the same Door Unit Number).
- For XP-SNET controller, the Door Unit Number ranges from "00" to "09" for a total of 10 connected doors.
|
.
.
Step 7: The following message window will be shown to indicate that the Record is Added. Click OK to continue.
Figure 12: Record Added window
Step 8: The Connection, Controller and Door settings are configured. Users can now observe the controller and door Status at Device List.
.
.
Step 1: After completing the Connection, Controller and Door settings, users can now check the status of the controller and door.
Step 2: To check the status of the controller, go to xPortalNet Server>Device List>Controller List to verify that the controller Status is Up.
Figure 13: Controller List under Device List tab
Step 3: To check the status of the door,go to xPortalNet Server>Devices List>Door Listto verify that the door StatusisUp.
Figure 14: Door List under Device List tab