Problem (Issue) Statement: | How to configure legacy XP-GT or XP-GTR controllers using network connection | ||||||||||||||||||||||||||||
Description: | XP-GT3200 / XP-GTR1200 controllers can connect to the Server PC running the xPortal software via network connections. This article will guide users on how to configure legacy XP-GT or XP-GTR controllers using network connection. | ||||||||||||||||||||||||||||
Related Software: |
| ||||||||||||||||||||||||||||
Related Hardware: |
| ||||||||||||||||||||||||||||
System Application: | NIL | ||||||||||||||||||||||||||||
Symptom and Finding: | NIL | ||||||||||||||||||||||||||||
Cause: | For first time guide on how to configure legacy XP-GT or XP-GTR controllers using network connection. | ||||||||||||||||||||||||||||
Solution: | Summary:
. Step-by-step Guide:
Step 1: Please perform the pre-configuration step for the network connection.
. .
Step 1: Users have to first identify the Server PC's IP address. Open Windows Command Prompt, type "ipconfig", and press Enter. Note down the IPv4 Address. Step 2: At the controller, enter Programming Menu
. . Step 3: Press 1 for System Menu > 7 for Network Settings. Follow the steps as highlighted in the following table. . . Step 4: Press the X key to return to the System Menu. Users will then be prompted to confirm saving the changes before exiting in the following window. Press the " . Step 5: Power off and re-power on the controller again to reset the controller in order for the changes to take effect. . .
Step 1: Go to xPortalNet Server > Server Admin > Connection Setup > Add. The Add Connection window will be shown. Configure the settings as shown in the screenshot. Click OK to save the changes. . Step 2: Go to xPortalNet Server > Server Admin > System Device Setup > Controller > Add. The Add Controller window will be shown. Configure the settings as shown in the screenshot. Click OK to save the changes. . Step 3: Go to xPortalNet Server > Server Admin > System Device Setup > Door > Add. The Add Door window will be shown. Configure the settings as shown in the screenshot. Click OK to save the changes. . Step 4: The newly added controller and door should have the status of "Up" in the Device List window. .
. Step 5: Users are advised to send the door settings to the controller. Go to xPortalNet Client > Device Comm > Send Door Settings > Select Controller > Send All Settings. . Step 6: At the controller's LCD screen, ensure that the PC icon at the top right corner is blinking, indicating that the controller successfully established communication with the Server PC. | ||||||||||||||||||||||||||||
Common Issues: | NIL | ||||||||||||||||||||||||||||
Porting Date: | 2/4/2019 |
...
Section | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||
|
.
...
.
Choices for confluence | ||
---|---|---|
|