Problem (Issue) Statement: | How to use Card + PIN mode for XP-M1000i controller | ||||||||||||||||||||
Description: | This article will guide users to configure XP-M1000i controller to be able to use Card + PIN mode in xPortalNet software. .
| ||||||||||||||||||||
Related Software: |
| ||||||||||||||||||||
Related Hardware: |
| ||||||||||||||||||||
System Application: | NIL | ||||||||||||||||||||
Symptom and Finding: | NIL | ||||||||||||||||||||
Cause: | For first time guide to configure XP-M1000i controller to be able to use Card + PIN mode in xPortalNet software. | ||||||||||||||||||||
Solution: | Summary:
. . Step-by-step Guide:
Step 1: Please follow the wiring diagram below for the connection between XP-M1000i controller to Plato-P80KLS reader. Note that the RC+ and RC- wires from the Plato-P80KLS reader is to be connected to the PC+ and PC- terminal on the XP-M1000i controller respectively. .
. .
Step 1: Ensure that the prerequisites settings for the XP-M1000i controller has been configured in xPortalNet software.
. . Step 2: Go to xPortalNet Client > Data Setup > Access Data Setting > Staff Records > Add. The Add Staff Detail window will be shown. Ensure that the Verification Mode field is selected to be "By Door". Click OK to save the changes and exit from the Add Staff Detail window. .
. . Step 3: Go to xPortalNet Client > Data Setup > System Setting > Door > select the affected Door > Edit. The Edit Door window will then be shown. At the Higher Security Mode field, select the "Token Type + PIN", and select the Higher Security TZ as "001" to ensure that Higher Security Mode is always on. Click OK to save the changes. .
| ||||||||||||||||||||
Common Issues: | NIL | ||||||||||||||||||||
Porting Date: | 13/02/2020 |
...
Section | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||
|
.
...
.
Choices for confluence | ||
---|---|---|
|