Step 1: Login to xPortalNet HS Server.
Step 2: Go to Server Admin > Connection Setup. The Connection Setup window will be shown as below.
Image Modified
Figure 2: Connection Setup window
Step 3: Click Add to add a new connection. The Add Connection window will be shown as below. Fill in the respective fields and click OK to save changes
Image Modified
Figure 3: Add Connection window
Image Modified
.
.
Step 1: Go to xPortalNet HS Server > Server Admin > System Device Setup > Controller. The Connection Setup window will be shown as below:
Image Modified
Figure 4: Controller Setup window
Step 2: Click Add to add a new controller device. The Add Connection Window will be shown as below. Fill up the respective field and click OK to save changes.
Image Modified
Figure 5: Add Controller window
Image Modified
Step 3: The following message window will be shown Record Added and click OKbutton.
Image Modified
Figure 6: Record Added window
.
.
Step 1: Go to xPortalNet HS Server > Server Admin > System Device Setup > Alarm Controller. The Alarm Controller Setup window will be shown as below:
Image Modified
Figure 7: Alarm Controller Setup Window
Step 2: Click Add to add a new alarm controller device. The Add Alarm Controller window will be shown as below. Fill in the respective fields and click OK to save changes.
Image Modified
Figure 8: Add Alarm Controller Window
Image Modified
Info |
---|
|
For internal I/O configuration on XP-GLS5000 controller, the Unit No field MUST be configured to "10" |
.
.
Step 3: The following message window will be shown Record Added and click OKbutton.
Image Modified
Figure 9: Record Added window
.
Info |
---|
|
Repeat steps 1 to 3 under this section for all extension boards (XP-SNET-E32R and XP-SNET-E248S) connected to the XP-GLS5000 controller board for alarm monitoring purposes. For applications where more than one extension board is connected to the XP-GLS5000 controller board, configure the address of the alarm panel in increasing order. For example, - 1st extension board address = "00", - 2nd extension board address = "01", - 3rd extension board address = "02" , and so on. In the Add Alarm Controller window, configure the Unit No. field according to the extension board address configured. |
.
.
Step 1: Go to xPortalNet HS Server > Server Admin > System Device Setup > Output Point. The Output Setup window will be shown as below:
Image Modified
Figure 10: Output Setup Window
Step 2: Click Add to add a new output device. The Add Output Window will be shown as below. Fill up the respective field and click OK to save changes.
Image Modified
Figure 11: Add Output Window
Image Modified
Info |
---|
|
The output point number starts from '0' for both extension boards XP-SNET-E32R and XP-SNET-E248. |
.
.
Step 3: The following message window will be prompted to show that Record is Added. Click OK to continue.
Image Modified
.
.
Step 1:Go to xPortalNet HS Server > Server Admin > System Device Setup > Input Point. The Input Setup window will be shown as below:
Image Modified
Figure 13: Input Setup Window
Step 2: Click Add to add a new input device. The Add Input window will be shown as below. Fill up the respective field and click OK to save changes.
Image Modified
Figure 14: Add Input Window
Image Modified
Info |
---|
|
The input point number starts from '0' for the XP-SNET-E248 extension board. |
.
.
Step 3: The following message window will be shown Record Added. Click OKto continue.
Image Modified
Figure 15: Record Added Window
Step 4: Users can then proceed to create an Instruction Control to configure the relationship between the Inputs and Outputs.