Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Problem (Issue) Statement:

How to setup alarm

monitoring system

monitoring system application using XP-GLS5000 controller at xPortalNet HS Server

Description:

A guide to configure alarm monitoring system application using XP-GLS5000 controller at xPortalNet HS Server.

Related Software:

  • xPortalNetHS v1.5.0.22

Related Hardware:

  • XP- GLS 5000 v1.16 and above
  • XP- SNET- E32R
  • XP- SNET- E248

System Application:

  • Alarm Monitoring System

Symptom and Finding:

NA

Cause:

For first time configuration for alarm monitoring system application using XP-GLS5000 controller at xPortalNet Server.

Solution:


Warning
titleWarning!
  • Users are not recommended to run any xPortal software in Windows XP operating system as the system is unstable

  • Users are also advised to stop the xPortal Services before shutting down the Server PC to prevent any missing transaction issues.

.

.

Summary:


Step-by-Step Guide:

  • Anchor
    running
    running
    Ensure that xPortalNet HS Services is Running:

Step 1: Open xPortalNet HS Comm Service.


Step 2: Ensure that the xPortalNet HS Comm Service Status is Running.
xPortalNet Comm Service Running Pop-up MessageImage Modified
Figure 1: xPortalNet

 

Comm Service Running Pop-up Message

 





  • Anchor
    connection
    connection
    To configure Connection Setup:

Step 1: Login to xPortalNet HS Server.


Step 2: Go to Server Admin Connection Setup. The Connection Setup window will be shown as below.
Connection Setup WindowImage Modified
Figure 2: Connection Setup window


Step 3: Click Add to add a new connection. The Add Connection window will be shown as below. Fill in the respective fields and click OK to save changes
Add Connection WindowImage Modified
Figure 3: Add Connection window


Image Modified
.

.

  • Anchor
    controller
    controller
    To configure Controller Setup:

Step 1: Go to xPortalNet HS ServerServer Admin System Device Setup Controller. The Connection Setup window will be shown as below:
Controller Setup WindowImage Modified
Figure 4: Controller Setup window


Step 2: Click Add to add a new controller device. The Add Connection Window will be shown as below. Fill up the respective field and click OK to save changes.
Add Controller WindowImage Modified
Figure 5: Add Controller window


Image Modified


Step 3: The following message window will be shown Record Added and click OKbutton.
Record Added WindowImage Modified
Figure 6: Record Added window
.

  • Anchor
    alarm
    alarm
    To configure Alarm Controller Setup:

Step 1: Go to xPortalNet HS ServerServer Admin System Device Setup Alarm Controller. The Alarm Controller Setup window will be shown as below:
Alarm Controller Setup WindowImage Modified
Figure 7: Alarm Controller Setup Window


Step 2: Click Add to add a new alarm controller device. The Add Alarm Controller window will be shown as below. Fill in the respective fields and click OK to save changes.
Add Alarm Controller WindowImage Modified
Figure 8: Add Alarm Controller Window


Image Modified


Info
titleNote

For internal I/O configuration on XP-GLS5000 controller, the Unit No field MUST be configured to "10"

.

.
Step 3: The following message window will be shown Record Added and click OKbutton.
Record Added WindowImage Modified
Figure 9: Record Added window

.

Info
titleNote

Repeat steps 1 to 3 under this section for all extension boards (XP-SNET-E32R and XP-SNET-E248S) connected to the XP-GLS5000 controller board for alarm monitoring purposes.

For applications where more than one extension board is connected to the XP-GLS5000 controller board, configure the address of the alarm panel in increasing order. For example,
 - 1st extension board address = "00", 
 - 2nd extension board address = "01", 
 - 3rd extension board address = "02" , 
and so on.

In the Add Alarm Controller window, configure the Unit No. field according to the extension board address configured.


.

.

  • Anchor
    output
    output
    To configure Output Setup:

Step 1: Go to xPortalNet HS ServerServer Admin System Device Setup Output Point. The Output Setup window will be shown as below:
Output Setup WindowImage Modified
Figure 10: Output Setup Window


Step 2: Click Add to add a new output device. The Add Output Window will be shown as below. Fill up the respective field and click OK to save changes.
Add Output WindowImage Modified
Figure 11: Add Output Window


Image Modified


Info
titleNote

The output point number starts from '0' for both extension boards XP-SNET-E32R and XP-SNET-E248.

.

.
Step 3: The following message window will be prompted to show that Record is Added. Click OK to continue.
Record Added WindowImage Modified

.

.

  • Anchor
    input
    input
    To configure Input Setup:

Step 1:Go to xPortalNet HS ServerServer Admin System Device Setup Input Point. The Input Setup window will be shown as below:
Input Setup WindowImage Modified
Figure 13: Input Setup Window


Step 2: Click Add to add a new input device. The Add Input window will be shown as below. Fill up the respective field and click OK to save changes.
Add Input WindowImage Modified
Figure 14: Add Input Window


Image Modified


Info
titleNote

The input point number starts from '0' for the XP-SNET-E248 extension board.

.

.

Step 3: The following message window will be shown Record Added. Click OKto continue.
Record Added WindowImage Modified
Figure 15: Record Added Window


Step 4: Users can then proceed to create an Instruction Control to configure the relationship between the Inputs and Outputs.

Info
titleKnowledge Base Link

Users can refer to How to Configure Instruction Control for Alarm Monitoring System Application at xPortalNet HS Client for the complete steps.


Common Issue

NA

Date Documentation:

29/5/2019

Status
subtletrue
colourYellow
titleproof-read

...

Section
bordertrue


Column
width100%

Related Articles.

Containing the label "xp-gls5000"

Filter by label (Content by label)
showLabelsfalse
max6
showSpacefalse
sorttitle
cqllabel = "xp-gls5000" and space = "MKB" and title ~ "!\"how to setup alarm monitoring system application using xp-gls5000 controller at xportalnet hs server\""


.

...

.

Choices for confluence
_id5d0b389d1b57ee00208d4f7e