Problem (Issue) Statement:

How to program Master Cards for XP-SR40 (legacy standalone controller)

Description:

XP-SR40 is a legacy standalone controller with a 40 card user capacity. The XP-SR40 requires the setting aside of 3 cards to be used as Master Cards, these Master Cards include:

  • Install Card (Master Card 1)
  • Delete Card (Master Card 2)
  • Delete All Cards (Master Card 3)

This article will guide users on how to program Master Cards for XP-SR40 controller.

Related Software:NIL
Related Hardware:
  • XP-SR40
System Application:NIL
Symptom and Finding:NIL
Cause:For first time guide on how to program Master Cards for XP-SR40 controller.

Summary:

  • To perform ColdStart operation for the XP-SR40 controller.

  • To install the three Master Cards for XP-SR40 controller.

.

Step-by-step Guide:

  • To perform ColdStart operation for the XP-SR40 controller:

Note

This section is only applicable for those applications where the programmed Master Cards are missing and users wished to re-program the Master Cards with new replacement cards. 

For first time installation of the three Master Cards, proceed to the next section.

.

.

Step 1: After powering the XP-SR40 controller, press and hold the exit button for 2 seconds.


Step 2: The XP-SR40 will beep every 1 second and the Green LED will be turned on. The EM lock will also be released. This is the Programming Mode of the controller.

.

.  

  • To install the three Master Cards for XP-SR40 Controller:

Step 1: In the Programming Mode (after first power up or ColdStart operation), flash the card intended to be Master Card 1 for Install Card, then followed by the card intended to be Master Card 2 for Delete Card and Master Card 3 for Delete All Cards.

Step 2: After the 3 Master Cards are programmed to the XP-SR40 controller, the controller will respond with the following responses:

  • Green LED will be turned off
  • buzzer will stop beeping
  • EM Lock will be turned on