Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Problem (Issue) Statement

How to configure XP-SNET Controller for Global Antipassback (GAC) Application

Description:

A guide to configure XP-SNET controller for Global Antipassback (GAC) application


Info
titleNote

XP-SNET-GAC controller is only supported for LAN Network Communications only.

.

Tip
titleTip

Controller models supported as GAC Client: XP-SNETv3.36, XP-SNETv4, XP-M2000i v6.10 and above, and XP-M1000i v6.00 and above.


Related Software:

  • xPortalNet v1.5.0.90 above

Related Hardware:

  • XP-SNET_GAC v2.24
  • XP- SNETv2 v3.36 and above

System Application:

  • Global Antipassback feature

Symptom and Finding:

NIL

Cause:

A guide to configure XP-SNET controller for Global Antipassback (GAC) application.

Solution:


Warning
titleWarning!

XP-SNET-GAC currently do not support odd numbered card lengths, e.g. 5, 7, 9 card number lengths.

Summary:


Step-by-step Guide:

  • Anchor
    1
    1
    To perform ColdStart for first power up:

Step 1: Press & hold COLDSTART button on XP-SNET board.


Step 2: Press & release RESET button on XP-SNET board.


Step 3: Wait for STAT & CPU LED to light up simultaneously.


Step 4: Release COLDSTART button.


Info
titleNote

User are advised to perform ColdStart operation once after every first time power up of the controller; or when advised to do so by the technical support.



  • Anchor
    2
    2
    To perform pre-configuration setting for the network connection:

Info
titleKnowledge Base Link

User may refer How to Pre-configure Network Connection for IP Controllers to complete the process.



  • Anchor
    3
    3
    To configure IP Address for XP-SNET:

Info
titleKnowledge Base Link

User may refer How to Configure IP Address for IP Controllers to complete the process.



  • Anchor
    4
    4
    To configure XP-SNET-GAC IP Address as the Master IP Address:

Info
titleKnowledge Base Link

This configuration process must be configured on XP-SNET controllers with firmware v3.71 or lower.



Step 1: After completing the process to configure the IP address. Users should scroll down the Network Setting page.


Step 2: Configure the Master Controller IP Address and Master Controller Port as XP-SNET-GAC's IP address and communication port respectively. Click Submit to save the changes made.
Configuring Master Controller IP Address and Master Controller PortImage Modified
Figure 1: Configuring Master Controller IP Address and Master Controller Port

Common Issue

NIL

Date Documentation:

3/10/2018 (Rev 1.0)

Status
subtletrue
colourYellow
titleProof-read

...

Section
bordertrue


Column
width100%

Related Articles.

Containing the label "antipassback-configuration"

Filter by label (Content by label)
showLabelsfalse
max56
showSpacefalse
sorttitle
cqllabel = "antipassback-configuration" and space = "MKB" and title ~ "!\"how to configure antipassback settings for single door controller in\""


.

...

.

Choices for confluence
_id5d0b04201b57ee00208d4bfe