Problem (Issue) Statement: | How to configure Time Set settings at XP-M1000X controller for standalone applications | ||||||||||
Description: | A guide to configure Time Set settings at XP-M1000X controller for standalone applications. Time Set is the time interval setting that defines the activation period of an operation or function. Time Set consists of three intervals of time period that gives the user options to have three-time intervals within a single day. Time Set "00" and "01" are default Time Sets. These time sets cannot be modified or deleted. Users definable Time Set numbers are from "02" to "49".
| ||||||||||
Related Software: | NIL | ||||||||||
Related Hardware: |
| ||||||||||
System Application: |
| ||||||||||
Symptom and Finding: | NIL | ||||||||||
Cause: | For first time guide to configure Time Set settings at XP-M1000X controller for standalone applications. | ||||||||||
Solution: | Summary:
|
Info | ||
---|---|---|
| ||
Users may refer to How to Enter into Programming Menu for XP-M1000x Controller for the complete steps to enter the Programming Menu. |
.
.
Step 2: Press 1 for Sys Menu > 3 for Time Set. The Set TimeSet screen will be shown on the controller. Enter the two digits value that represent the Time Set number that users wished to configure. Note that user-definable Time Set values are from "02" to "49".
Figure 2: Set TimeSet Screen
.
Step 3: The following screen will then be shown to prompt users to configure Interval 1 (I1) of the Time Set. Enter four digits value that corresponds to HHMM at each field. Note that these time intervals are in 24 hour format. Press # to save the changes.
Figure 3: Set First Interval for the Time Set
.
Step 4: The controller screen will then prompt users to configure Interval 2 and 3 (I2 and I3) respectively. Configure the values accordingly. When all three intervals are configured, the controller screen will prompt the following screen to ask users to confirm saving the changes. Press # to confirm saving the changes to the Time Set.
Figure 4: Save Changes Screen
.
Step 5: The controller screen will then return to Set TimeSet screen. Press * to return to the Sys Menu.
.
Step 6: Users can now proceed to configure the Time Zone settings in XP-M1000X controller for standalone applications.
Info | ||
---|---|---|
| ||
Users may refer to How to Configure Time Zone Settings at XP-M1000X Controller for Standalone Applications for the complete steps to configure Time Zone settings. |
Common Issue
NIL
Date Documentation:
24/4/2020 (Rev 1.0)
...
Section | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||||
|
.
...
.
Choices for confluence | ||
---|---|---|
|