Info |
---|
title | To Configure IP Address: |
---|
|
Users can choose EITHER one of the 3 methods to configure the GT/GTR controller's IP address. |
.
.
Warning |
---|
|
Method 3 is only available to xPortal3000 software. |
.
.
.
.
Step 1: Press and hold the ColdStart button on the controller board.
.
Step 2: Turn OFF the power supply.
.
Step 3: Turn ON the power supply.
.
Step 4: Release the ColdStart button after 3 seconds. The controller will respond with a long beep to indicate that the ColdStart process is in effect.
.
.
.
.
Step 1: Open IE browser (Internet Explorer) and type the default IP address in the address box.
Info |
---|
|
Default IP address for GT/GTR controllers: 192.168.1.20 |
.
.
Step 2: The Windows Security dialog box will be shown. Enter the User name and Password and click OK to continue.
Info |
---|
|
Default User Name: admin Password: password10 |
.
.
Figure 1: The Windows Security Dialog Box
Step 3: Once the login is successful, the following home window will be shown:
Figure 2: The Web Diagnostic Home Window
Step 3: Go to Configuration > Network. The Network Setting window will be shown. Configure the Controller's IP address, Subnet Mask, Gateway and Server PC's IP address settings. Click Save Setting to save the changes made.
Figure 3: The Network Setting Window
.
Info |
---|
|
- Once the settings are saved, the Web Diagnostic is only accessible via the newly changed controller IP address.
- The controller and Server PC's IP addresses are required to be configured with static IP addresses.
- The communication port between Server and controller is of ÚDP type with default port number: 6268.
- Ensure Server and controller's IP addresses are unique IP addresses in the network and that both IP addresses are not already occupied by another device / controller.
- Ensure that the setting for Enhanced Network Encryption (AES 128) is configured to be the same as the controller setting in the xPortalNet software. If the setting on Web Diagnostic does not match with the setting in the software, the controller will also be shown as "Down"
|
.
.
Step 1: The following home screen will be shown at the controller's LCD:
Figure 4: Controller LCD Home Screen
.
Step 2: To enter Configuration Menu for the first time, press asterisk key (*) and enter the 6-digits default MasterPIN.
Info |
---|
|
Default MasterPIN: 123456 |
.
.
Figure 5: Entering default MasterPIN for first time login
Step 3: The following window will then be shown to prompt users to enter a new MasterPIN which will be used for subsequent logins to enter Configuration Menu.
Figure 6: The Change MasterPIN Window
Step 4: Re-enter the same Master Pin and press √ to confirm the new 6-digits MasterPIN.
Figure 7: Re-enter the Same MasterPIN to confirm the MasterPIN
Step 5: The following window will be shown once the new MasterPIN is updated successfully.
Figure 8: The MasterPIN Updated Window
Step 6: Press the asterisk (*) key, followed by the new MasterPIN to enter Configuration Menu. The following Main Menu window will be shown upon entering Configuration Menu.
Figure 9: The Main Menu Window
Step 7: Press 1 for System Menu. Press 7 to access the Network Settings menu. The following window will be shown. Enter the Local IP Address for the controller and press √ to proceed to the next window.
Figure 10: Enter the Local IP Address
Step 8: At the following window, enter the Local Port No for the controller and press √ to proceed to the next window.
Figure 11: Enter the Local Port No
.
Warning |
---|
|
The Port No. setting here MUST be the same as the setting for the software. Users are advised to use the default port no. |
.
.
Step 9: Next, enter the Remote IP Address for Server's PC and press √ to proceed to the next window.
Figure 12: Enter the Remote IP Address (Server PC)
Step 10: The following window will be shown. Enter the Remote Port No. for the Server PC and then, press √ to proceed to the next window.
Figure 13: Enter the Remote Port No (Server PC)
.
Warning |
---|
|
The Port No. setting here MUST be the same as the setting for the software. Users are advised to use the default port no. |
.
.
Step 11: At the following window, enter the Subnet Mask for the network and press √ to proceed to the next window.
Figure 14: Enter the Subnet Mask
Step 12: Enter the Gateway IP for the network at the following window and press √ to proceed to the next window.
Figure 15: Enter the Gateway Setting
Step 13: Once users have completed all the settings, the following window will be shown to prompt users to save all changes Press √ to save all configuration settings. The controller will then auto restart to allow the changes to take effect immediately.
Figure 16: The Save Changes? Window
.
Info |
---|
|
If users leave the process at any stage, all changes made previously will not be saved and will be lost. To save the network changes, press √ until users reach this window and press √ again to confirm saving the changes. |
.
.
Step 1: Login to xPortal3000 Client software and click Device Lookup.
Figure 17: The Device Lookup Icon
Step 2: The Device Discovery window will start searching for connected controller from the network.
Figure 18: The Device Discovery Window Searching for Controllers
Step 3: Select the detected controller and then click Configure Controller to change the controller settings.
Figure 19: Configuring the Detected Controller
Step 4: The following window will then be shown. Assign a new IP address, Subnet Mask, Gateway and Server IP address. Click OK to confirm and save the changes.
Figure 20: The Network Setting Window
.
Info |
---|
|
- The controller and Server PC's IP addresses are required to be configured with static IP addresses.
- The communication port between Server and controller is of ÚDP type with default port number: 6268.
- Ensure Server and controller's IP addresses are unique IP addresses in the network and that both IP addresses are not already occupied by another device / controller.
- Ensure that the setting for Enhanced Network Encryption (AES 128) is configured to be the same as the controller setting in the xPortalNet software. If the setting on Web Diagnostic does not match with the setting in the software, the controller will also be shown as "Down"
|
.
.
Step 5: The window will prompt users to enter the user name and password. Enter the web diagnostic user name and password to proceed.