Problem (Issue) Statement: | How to configure XP-SNET controller using RS485 connection in xPortalNet software | |||||||||||||||||||||||||||||||||||||||||||
Description: | This article will guide users to configure XP-SNET controller using RS485 connection in xPortalNet software | |||||||||||||||||||||||||||||||||||||||||||
Related Software: |
| |||||||||||||||||||||||||||||||||||||||||||
Related Hardware: |
| |||||||||||||||||||||||||||||||||||||||||||
System Application: | NIL | |||||||||||||||||||||||||||||||||||||||||||
Symptom and Finding: | NIL | |||||||||||||||||||||||||||||||||||||||||||
Cause: | For first time guide to configure XP-SNET controller using RS485 connection in xPortalNet software | |||||||||||||||||||||||||||||||||||||||||||
Solution: | Summary:
. . Step-by-step Guide:
Step 1: Connect the XP-SNET controller to the Server PC properly via the MCI or RS485 converter.
. . Step 2: If the controller is connected to Server PC via MCI, ensure that the MCI is powered up and working properly. . .
Step 1: At the Server PC, go to Control Panel > System and Security > Windows Firewall > Turn Windows Firewall on or off. The following window will be shown. Select Turn off Windows Firewall. .
. .
Step 1: Ensure that the MCI or RS485 to USB converter is detected by the Server PC. Check via the Device Manager window. Note that the MCI is connected to COM4. . Step 2: Go to xPortalNet Server > Server Admin > Connection Setup > Add. The Add Connection window will be shown. Configure the settings as shown in the screenshot below, and selecting the comm port number where the MCI or RS485-to-USB converted is detected. Click OK to save the changes. .
. . Step 3: Go to xPortalNet Server > Server Admin > System Device Setup > Controller > Add. The Add Controller window will then be shown. Configure the settings as shown in the screenshot below. Click OK to save the changes. .
. . Step 4: Go to xPortalNet Server > Server Admin > System Device Setup > Door > Add. The Add Door window will be shown. Configure the settings as shown in the screenshot below. Click OK to save the changes. .
.
. . Step 5: Back at the home window of the software, go to Device List > Controller tab. Ensure that the newly added controller status is shown as "Up". . Step 6: Go to the Door tab and ensure that the newly added door status is also shown as "Up" and state is shown as "Door Closed". | |||||||||||||||||||||||||||||||||||||||||||
Common Issues: | NIL | |||||||||||||||||||||||||||||||||||||||||||
Porting Date: | 30/01/2020 |
...