Problem (Issue) Statement:

How to configure Door Access Level at xPortalNet software

Description:

A guide to configure Door Access Level at xPortalNet software. This article will guide users to setup a Door Accessibility Level (Door Access Level) by setting the accessible Time Zone for each door. The Door Accessibility Level will then be assigned to individual card users to allow the system to determine the day and time the card user can gain access to the door.

Related Software:

  • xPortalNet Lite
  • xPortalNet Standard
  • xPortalNet PS

Related Hardware:

  • All controller model

System Application:

  • Software configuration for assign door accessibility level

Symptom and Finding:

NA

Cause:

For first time configuration on Door Access Level at xPortalNet software.

Solution:

Summary

  • To setup Door Accessibility Schedule in xPortalNet.

Step-by-step Guide:

  • To setup Door Accessibility Schedule in xPortalNet:

Step 1: Ensure that xPortalNet Services is running.


Step 2: Go to xPortalNet Client > Data Setup > Access Data Setting > Door Accessibility Schedule > Add.


Step 3: The Add Door Accessibility window will be shown as below. Fill in all the necessary fields and click OK to save the changes.
Add Door Accessibility Window
Figure 1: Add Door Accessibility Window





Info
titleNote
  • Only XP-SNETv4 controller can support start / end date checking for Door Accessibility Schedule.
  • xPortalNet software is able to support up to a maximum of 255 sets of Door Accessibility Schedules.
  • The software has 2 default Door Access Levels, which are access code "000" for "No Access" and "001" for "Free Access".



Info
titleKnowledge Base Link

Users can refer to How to Configure Time Zone Settings in xPortalNet Software to configure the Time Zone settings.



Step 4: The following message window will be shown to indicate that the Door Accessibility Schedule has been added successfully. Click OK to continue.
Door Accessibility is Added Successfully Window
Figure 2: Door Accessibility is Added Successfully Window


Step 5: The Send Data and Command window will be shown. Please wait for the Send Data and Command process to complete before clicking Close.
Send Data and Command Window
Figure 3: Send Data and Command Window

Date Documentation:

4/6/2018 (Rev 1.0)

Status
subtletrue
colourYellow
titleProof-read

.

Section
bordertrue


Column
width100%

Related Articles.

Containing the label "xportalnet" AND "setup-guide"

Filter by label (Content by label)
showLabelsfalse
max6
showSpacefalse
sorttitle
cqllabel = "xportalnet" and label = "setup-guide" and space = "MKB" and title ~ "door !\"how to configure door access level at xportalnet software\""