Problem (Issue) Statement: | How to configure address unit no on XP-SNET-E32R extension board | ||||||||||
Description: | A guide to configure address unit no on XP-SNET-E32R extension board. | ||||||||||
Related Software: | NA | ||||||||||
Related Hardware: |
| ||||||||||
System Application: |
| ||||||||||
Symptom and Finding: | NA | ||||||||||
Cause: | For first time configuration for address unit no on XP-SNET-E32R extension board. | ||||||||||
Solution: | Summary
|
Info | ||
---|---|---|
| ||
Ensure that XP-SNET controller is configured to Lift Controller Mode. Users may refer to /wiki/spaces/MICS/pages/874152144 How to Assign XP-SNET Controller to Function as Lift Controller for the complete steps. |
To configure DIP switches for address setting on XP-SNET-E32R extension board:
Step 1: The XP-SNET-E32R address setting for the DIP switch can be referred to as shown below:
Figure 1: The DIP switches for address setting location on the XP-SNET-E32R extension board
Step 2: The table below shows the different DIP switch configurations for the respective address settings:
Step 3: The table below shows an example of the DIP switches settings for a XP-SNET-E32R extension board to be configured with address setting of unit no. "01":
Info | ||
---|---|---|
| ||
The address of the extension boards must be unique (ranging from '00' to '03'), i.e.: no two extension boards in the same connection network can have the same address. |
To observe the XP-SNET and XP-SNET-E32R response after configuring the address of XP-SNET-E32R:
Step 1: On the XP-SNET controller, ensure that both D33 & D34 LEDs in the "Downlink" section (lower left section of XP-SNET controller) is blinking to indicate that the XP-SNET controller has successfully established communication with the XP-SNET-E32R extension board.
Step 2: On the XP-SNET-E32R extension board, ensure that both Uplink LEDs are blinking. All output relay LEDs on the XP-SNET-E32R extension board will then be turned ON.