Problem (Issue) Statement:How to configure XP-M1000i or XP-M1300i controller using RS485 or RS232 connection
Description:

This article will guide users on how to configure XP-M1000i or XP-M1300i controller using RS485 or RS232 connection.

Related Software:NIL
Related Hardware:
  • XP-M1000i
  • XP-M1300i
System Application:NIL
Symptom and Finding:NIL
Cause:For first time guide on how to configure XP-M1000i or XP-M1300i controller using RS485 or RS232 connection.
Solution:
  • Anchor
    1
    1
    To check Comm Port No connected to MCI or Serial-to-USB converter:

Step 1: Access the Windows Device Manager. Right-click at Computer > Manage.
Right-click Computer and Click Manage
Figure 1: Right-click Computer and Click Manage

.

Anchor
step2
step2
Step 2: The Computer Management window will be shown. Select Device Manager and expand the Ports (COM & LPT) menu.

If the MCI or Serial-to-USB converter is connected via RS232, the device will appear as a Communication Ports
Identifying Comm Port No for RS232 Connection
Figure 2: Identifying Comm Port No for RS232 Connection

.

If the MCI or Serial-to-USB converter is connected via RS485, the device will appear as a USB to Serial Bridge
Identifying Comm Port No for RS485 Connection
Figure 3: Identifying Comm Port No for RS485 Connection

.

.

  • Anchor
    2
    2
    To configure software settings:

Warning
titleWarning!
  • Users are not recommended to run any xPortal software in Windows XP operating system as the system is unstable

  • Users are also advised to stop the xPortal Services before shutting down the Server PC to prevent any missing transaction issues.

.

.

Step 1: Go to xPortalNet Server > Server Admin > Connection Setup > Add. The Add Connection window will be shown. Fill in the information following the screenshot below, with the Comm No following the Comm Port No obtained in step 2 of the previous section.
Add Connection Window
Figure 4: Add Connection Window

.

Step 2: Go to xPortalNet Server > Server Admin > System Device Setup > Controller > Add. The Add Controller window will be shown. Fill in the information following the screenshot below, with the Unit No setup according to the controller address number.
Add Controller Window 
Figure 5: Add Controller Window

.

Step 3: Go to xPortalNet Server > Server Admin > System Device Setup > Door > Add. The Add Door window will be shown. Fill in the information following the screenshot below, ensuring that the Unit No field is configured to "0".
Add Door Window
Figure 6: Add Door Window

.


Info
titleNote

Under the Controller field, select the controller name added in Step 2.

Note that in Step 2, the example controller is named MDC, hence the Controller field in Figure 6 is designated as MDC.


.

.

Step 4: At the software home window, go to Device List > Controller. Ensure that the status of the newly added controller is shown as "Up".
Controller List Window
Figure 7: Controller List Window

.

Step 5: At the software home window, go to Device List > Door. Ensure that the status of the newly added door is shown as "Up".
Door List Window
Figure 8: Door List Window

.

Step 6: Go to xPortalNet Client > Device Comm > Send Door Settingselect the newly added controller > Send All Settings. The software will send the newly configured settings to the controller.

Common Issues:NIL
Porting Date:17/4/2019

...