Problem (Issue) Statement: | How to configure AntiPassback settings for single door controller in xPortal3000 software | |||||||||||||||||||||||||||||||||||||||||||||
Description: | A guide to configure AntiPassback settings for single-door controller in xPortal3000 software. | |||||||||||||||||||||||||||||||||||||||||||||
Related Software: |
| |||||||||||||||||||||||||||||||||||||||||||||
Related Hardware: |
| |||||||||||||||||||||||||||||||||||||||||||||
System Application: |
| |||||||||||||||||||||||||||||||||||||||||||||
Symptom and Finding: | NIL | |||||||||||||||||||||||||||||||||||||||||||||
Cause: | For first time configuration on AntiPassback settings for single door controller in xPortal3000 software. | |||||||||||||||||||||||||||||||||||||||||||||
Solution: |
. . Summary:
|
Anchor | ||||
---|---|---|---|---|
|
Step 1: Go to xPortal3000 Client > Hardware > Controller.
Figure 1: Controller Icon in Hardware Menu
Step 2: Select the specific controller(s) to enable AntiPassback feature in Controller Setup window and click Modify. The Edit Controller window will be shown as below.
Figure 2: Edit Controller Window
Step 3: Under General Settings tab, for the AntiPassback Function Enable field, click on the drop-down dialog box and select Yes. Click OK to save the changes.
Figure 3: AntiPassback Function Enable Field in General Settings Tab
Step 4: The software will then prompt the following message window to indicate that the Record is updated. Click OK to continue.
Figure 4: Record Updated Window
Step 5: The Delivery Report window will then be shown. Wait for the send door setting process to complete before clicking Close to continue.
Figure 5: Delivery Report Window
.
.
To configure Zone Code in Door Setup:Anchor configurezonecode-106 configurezonecode-106
Step 1: Go to xPortal3000 Client > Hardware > Door.
Figure 6: Door Icon in Hardware Menu
Step 2: Select the specific door to configure zone code in Door Setup window and click Modify to continue. The Edit Door window will be shown.
Figure 7: Edit Door Window
Step 3: Under the Advanced Settings tab, configure the AntiPassback Entry & Exit Zone Code and click OK to save the changes.
Figure 8: AntiPassback Entry and Exit Zone Code Settings
Info | ||
---|---|---|
| ||
Entry & Exit Zone Code cannot be the same value. System users can configure such that same spaces can have the same zone code, while different spaces have different zone codes. When a user enters from one space to the other using a door, the zone code will be updated to reflect the space that the user is in. |
Step 4: The following message window will be shown to indicate that the Record is updated. Click OK to continue.
Figure 9: Record Updated Window
Step 5: The Delivery Report window will then be shown. Wait for the send door setting process to complete before clicking Close to continue.
Figure 10: Delivery Report Window
.
.
To configure AntiPassback settings in Staff Records:Anchor configureantipassback-106 configureantipassback-106
Step 1: Go to xPortal3000 Client > Staff Record.
Step 2: The Staff Detail Setup window will be shown. Select the card user intended to enable the AntiPassback feature and click Modify.
Figure 11: Staff Detail Setup Window
Step 3: The Edit Staff Detail window will be shown. Under the General Info tab, in the AntiPassback Enabled field, click the drop-down dialog box and select Yes to enable Antipassback feature. Click OK to save the changes.
Figure 12: General Info Tab in Edit Staff Detail Window
Info | ||
---|---|---|
| ||
|
Step 4: The following message window will be shown to indicate that the Record is updated. Click OK to continue.
Figure 13: Record Updated Window
Step 5: The Delivery Report window will then be shown. Wait for the send door setting process to complete before clicking Close to continue.
Figure 14: Delivery Report Window
.
.
To verify that the AntiPassback feature is enabled:Anchor verifyantipassback-106 verifyantipassback-106
Step 1: Use a test card to flash on the Entry and Exit Readers. Ensure that the Latest Event List recorded the Valid Entry / Exit Access transactions.
Figure 15: Valid Entry and Exit Access Transaction Logs
Step 2: Using the same card, flash on the Entry Reader more than twice. Ensure that the Latest Event List records one Valid Entry Access transaction and followed by continuous AntiPB Violation transaction logs.
Figure 16: Latest Event List Showing AntiPB Violation Transaction Logs
.
.
To clear AntiPassback status for the card user:Anchor clearantipassback-106 clearantipassback-106
Step 1: Go to xPortal3000 Client > Device Comm > Send Card Setting.
Figure 17: Send Card Setting Icon in Device Comm Menu
Step 2: The Send Card Settings window will be shown. Select the Controller and card holder whose AntiPassback status is to be cleared and click Clear Anti PB.
Figure 18: Clear Anti PB Icon in Send Card Settings Window
Step 3: The Delivery Report window will then be shown. Wait for the send clear antiPB process to complete before clicking Close to continue.
Figure 19: Delivery Report Window
Step 4: Flash the card on Entry Reader again and verify that the user should be able to access the door. The Latest Event List in xPortal3000 software should record a Valid Entry Access or Valid Exit Access transactions.
Date Documentation:
2/7/2018
...
Section | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||
|
.
...
.
Choices for confluence | ||
---|---|---|
|