Problem (Issue) Statement: | How to configure extra input and output to trigger barrier gate via loop detector in xPortalNet Software | ||||||||||||||||||||||||||||||||
Description: | This article will guide users to configure the extra input and output on controller board to trigger barrier gate via loop detector in the xPortalNet software, Many project installations use MicroEngine controller for Barrier Gate Access System without installing any readers. The barrier gate will receive signal from loop detector directly to trigger the gate to open automatically without requiring users to flash any cards to a reader. | ||||||||||||||||||||||||||||||||
Related Software: |
| ||||||||||||||||||||||||||||||||
Related Hardware: |
| ||||||||||||||||||||||||||||||||
System Application: |
| ||||||||||||||||||||||||||||||||
Symptom and Finding: | NIL | ||||||||||||||||||||||||||||||||
Cause: | For first time guide to configure Loop Detector as Input in xPortalNet software to trigger (Open) barrier gate. | ||||||||||||||||||||||||||||||||
Solution: | Summary:
.. Step-by-step Guide:
Step 1: After adding Connection, Controller and Door, users must add an alarm controller. . Step 2: Go to xPortalNet Server> Server Admin > System Device Setup > Alarm Controller. . Step 3: The Alarm Controller Setup window will be shown. Click Add. . Step 4: The Add Alarm Controller window will be shown. Fill the details and take note on the highlighted fields. Click OK to save the changes. .
. .
Step 1: Go to xPortalNet Server > Server Admin > System Device Setup > Input Point. . Step 2: The Input Setup window will be shown. Click Add. . Step 3: The Add Input window will be shown. Fill in the details according to the table below. Click OK to continue after filling in the details. . . Step 4: The Record Added! window will be shown. Click OK to continue. . Step 5: User will return to the Input Setup page. Click Close to exit. . Step 6: The Request submitted to reload Input list! window will be shown. Click OK to continue. . .
Step 1: Go to xPortalNet Server > Server Admin > System Device Setup > Output Point. . Step 2: The Output Setup window will be shown. Click Add. . Step 3: The Add Output window will be shown. Fill the details according to the table below. . . Step 4: Next, fill in the details on Event Trigger On section accordingly. Click OK to continue. . . Step 5: The Record Added! window will be shown. Click OK to continue. . Step 6: User will return to the Output Setup page. Click Close to continue. . Step 7: The Request submitted to reload Input list! window will be shown Click OK to continue. . .
Step 1: Go to xPortalNet Client > Device Comm > Send Door Setting. The Send Door Controller Settings window will be shown. . Step 2: Select the respective controller and click Send All Setting. . Step 3: The following Send Data and Command window will be show as below, please wait a while. . Step 4: Next, the Delivery Report will be shown once the send data to controller process is completed. Ensure that all of the sending data is completed without any errors, as it may affect the controller operation. . .
Step 1: User may go to xPortalNet Client to monitor transaction from controller at Latest Event Transaction page shown as below. . Step 2: The xPortalNet software will record the following transactions when the input point configured for the barrier gate is activated. The various transactions are explained in the table that follows. . | ||||||||||||||||||||||||||||||||
Common Issue | NIL | ||||||||||||||||||||||||||||||||