Problem (Issue) Statement: | How to configure XP-M1000x for Car Park Mode | ||||||||||
Description: | This article will guide users on how to configure XP-M1000x for Car Park Mode. | ||||||||||
Related Software: | NIL | ||||||||||
Related Hardware: |
| ||||||||||
System Application: | NIL | ||||||||||
Symptom and Finding: | NIL | ||||||||||
Cause: | For first time guide on how to configure XP-M1000x for Car Park Mode. | ||||||||||
Summary:
. Step-by-step Guide:
Step 1: Please refer to the following wiring diagram for the connections between the XP-M1000x controller to the reader units: . . Step 2: Alternatively, users can also connect the XP-M1000x controller to MAS-RBU relay boards by referring to the following wiring diagram. . . .
Step 1: Power up the controller. . Step 2: Enter the Programming Menu.
. . Step 3: Press 1 for Sys Menu > 6 for General Para. The General Parameter Setting screen will be shown. Press # to toggle between settings until the System Mode parameter is shown as below: .
. . Step 4: Press 0 to cycle from one mode to another. The default operation mode is "DA". Keep pressing the # key until the save changes screen is shown, and press the # key again to save the changes. | |||||||||||
Common Issues: | NIL | ||||||||||
Porting Date: | 2419/46/2019 |