9: The Delivery Report window will then be shown. Click OK.
Anchor |
---|
| setup-mifare-reader-95 |
---|
| setup-mifare-reader-95 |
---|
|
To setup the Mifare sector programming reader:
Step 1: Go to xPortalNet Client > Data Setup > Data Access Setting > Staff Record > Get Now! > Mifare Card Programming.
Image Modified
Figure 6: Mifare Card Programming Icon in Staff Detail Setup Window
Step 2: Click Reader Settings in the Mifare Card Programming icon.
Image Modified
Figure 7: Reader Settings Button in Mifare Card Programming Icon
Step 3: The following message window will be shown to indicate that the software did not detect a serial port. Click OK to continue.
Image Modified
Figure 8: No Serial Port Detected Window
Step 4: The Reader Settings window will then be shown. Select "Third-Party" at the Reader Selection field and confirm the Model Name of the Mifare sector programmer. Click OK to save the changes.
Image Modified
Figure 9: Reader Settings Window
Anchor |
---|
| write-card-95 |
---|
| write-card-95 |
---|
|
To write card ID number (Card No field in Add Staff Detail window) to Mifare card sector:
Step 1: Add a new staff / card user via the Add Staff Detail window. At the Card No. field, specify the card ID number to be programmed to the Mifare card sector.
Info |
---|
|
To program card ID for an existing user, skip to step 2. |
Step 2: At the Staff Detail Setup window, select the card user to program the card ID (Card No. in Add Staff Detail window) and place the blank card on OMNIKEY card reader.
Image Modified
Figure 10: Staff Detail Setup Window
Step 3: Click Mifare Card Programming and select Write Card.
Image Modified
Figure 11: Write Card Button in Mifare Card Programming Icon
Step 4: Software will begin to write Card No. into Mifare card sector. Wait for the process to complete.
Image Modified
Figure 12: Operation in Progress Window Showing that the Mifare Card Programming is Completed
Step 5: Once the process is completed, the following message window will be shown to indicate that the Enrolment of Mifare card settings has succeed. The Mifare card can now be removed from the OMNIKEY reader.
Image Modified
Figure 13: Enrolment of Mifare Card Settings Succeed Window
To read card ID number (Card No field in Add Staff Detail window) from Mifare card sector:
Step 1: Place the programmed Mifare card on the OMNIKEY reader.
Step 2: Go to Mifare Card Programming and select Read Card.
Image Modified
Figure 14: Read Card Button in Mifare Card Programming Icon
Step 3: The software will read the Card No from Mifare card sector and the information of the card will be shown as below.
Image Modified
Figure 15: Details of the Read Mifare Card